Snap-Locking Waterproof Connectors with Pre-Filled Silicone
LV 9000 & LV 9500
- Perfect for bundling your commons.
- Best low-voltage connections for landscape lighting, irrigation & more...
- 100% Waterproof
- Quick, compact and easy!
Blazing Wire Connectors LV 9000 and LV 9500 are the low-voltage wire connectors designed for the professional irrigation and landscape lighting contractor. Unlike twist-on connectors, you never have to doubt the connection.
Superior Performance When it Counts
- Lawn Irrigation Systems
- Low-Voltage Landscape Lighting
- Security Systems
- Telephone Wire Splices
- Boats, Recreational Vehicles
- Heavy Construction Equipment
Snap-Locking connectors eliminate common install problems:
Locking |
- Never loosens or dangles off wires |
Foolproof |
- Never fails to grab the wires |
Easy |
- Compact 5-second installation |
No Mess |
- Silicone encapsulates connection and will not melt out |
No Tunneling Effect |
- No channel for moisture to follow into the connection |
Vibration Proof |
- Connection stays secure |
Locks Tight with Double O-Ring Seals
Just squeeze and lock to hydraulically pump and pack waterproofing silicone. Pre-filled silicone fully encapsulates all bare wires, closing all entryways against moisture and corrosion. A double O-ring seal bars water from creeping in, and latches lock the connector around the wires. Blazing Wire Connectors™ are vibration-proof and never dangle off the wires.
Say Goodbye to Traditional Connector Problems
Are you familiar with the traditional problems of "waterproof" low-voltage wiring?
- When you go back to a valve box, do you find connectors dangling off the ends of the wires?
- When installing, do you twist and twist and the twist-on connectors still don't grab the wires?
- Do you regularly have to pull out the wires, removing the silicone with them?
- Do you overtwist and the wires break off inside?
- Do you have to turn your connector upside down so it doesn't collect water?
- Is it too messy if you ever have to get back into the connection?
Technical Specs
Blazing Wire Connectors™ Installation Instructions
(Formerly known as SNAPLOC™ Low-Voltage Wire Connectors.)
Additional Tools Required: None.
INSTRUCTIONS FOR LV 9000:
- Strip wires 3/4" and group bare wire ends together. No pre-twisting necessary with solid wire. Pre-twist stranded wire. If using both wire types, wrap stranded wire around solid wires (see illustration 1A).
- Insert wires through flexible sealing fingers and bend wires into either "V-Channel".
- Push inner sleeve into pre-filled outer sleeve until double-locked. Pre-filled silicone fully waterproofs the connection. Do not reuse connector.
INSTRUCTIONS FOR LV 9500:
- Strip wires 1" and group bare wire ends together. No pre-twisting necessary with solid wire. Pre-twist stranded wire. If using both wire types, wrap stranded wire around solid wires (see 1A).
- Insert wires through flexible sealing fingers and bend wires into one "V-Channel". For large wires or large combinations, use the "V-Channel" with round hole at bottom; pull wires into hole below "V". To bend heavy solid wires, use bending sleeve / depth gauge on outer sleeve of connector.
- Push inner sleeve into pre-filled outer sleeve until double-locked. Pre-filled silicone fully waterproofs the connection. Do not reuse.
Extended Information
Blazing Wire Connectors™ Product Specifications
(Formerly known as SNAPLOC™ Low-Voltage Wire Connectors.)
The LV 9000 and LV 9500 wire connectors can be used with both solid and stranded wires.
Blazing Wire Connectors™ applications include:
- Lawn Irrigation Systems
- Low-Voltage Landscape Lighting
- Security Systems
- Telephone Wire Splices
- Boats, Recreational Vehicles
- Heavy Construction Equipment
LV 9000 / (small)
- WIRE SIZES: Minimum 2 #24 gauge wires; Maximum 5 #18
- APPLICATION: Maximum 30 Volts / 10 Amps. Copper and/or aluminum wire, solid or stranded
- SEALANT TEMPERATURE: -40°F to 400°F
- WARNING! Not for high-voltage connections.
LV 9500 / (large)
Designed specifically for landscape lighting, golf courses, and larger irrigation wiring.
- WIRE SIZES: Minimum 2 #18 gauge wires; Maximum 3 #10 & 1 #18
- APPLICATION: Maximum 30 Volts Copper and/or aluminum wire, solid or stranded
- SEALANT TEMPERATURE: -40°F to 400°F
- WARNING! Not for high-voltage connections.